Galaxy
Pilot Control Panel ![]()
The Galaxy Pilot Control Panel is a remote panel that receives information from the Galaxy and will control the fans and door position at a remote setting. The Galaxy Panel requires a special U5_Pilot software to activate this feature.
The Galaxy sends out the Mode and current Setpoint. The Pilot
will respond only to Shutdown, Cooling, and Timed. All other Galaxy
modes will be referred to as Standby on the Pilot. During Cooling
the Pilot will turn on the fans and produce a 4-20ma output to modulate
and control the door for the Galaxy Setpoint. For Shutdown and
Standby the fans will be turned off and the 4-20ma output to stay at 4ma and
keep the door closed.
The Pilot has its own Plenum sensor and will produce a Sensor Alarm if
the sensor goes out of range. The fans will shut off, and the door will
close.
If communication is lost, a Com. Fail alarm will occur on the Pilot and the fans will shut off and the door will close.
The remote door requires a second Low Temp sensor and will cause the Galaxy to go into a low temp shutdown.
Return to Galaxy Control Panel
To learn more about the Galaxy Pilot Control Panel, please contact us - click here.